How Storage Works, Part 4: PCIe Gen6 and Gen7 for Storage

What PCIe Gen6 changes for SSDs: the 256-byte flit and its cost, FEC and replay, L0p, OCP power and heat limits, the first Gen6 drives, and PCIe 7.0 and 8.0.

On this page 7 sections

PCIe Gen6 doubles the lane rate to 64.0GT/s, but for storage the changes that matter sit behind that number. Every Gen6 link sends data in fixed 256-byte units called flits, protected by forward error correction (FEC) and a cyclic redundancy check (CRC), and the same generation adds a link state that saves power while traffic keeps moving. Flash Foundations Part 1 gives the generation ladder, and Part 10 explains the PAM4 signal and the PCIe 7.0 release.

PCIe Gen6 for storage: a flit with payload and link fields, a link narrowing to fewer active lanes, and a temperature scale with throttle marksA three-panel schematic. Left: a wide teal payload field followed by three thin copper link fields, above a row of small flit slots. Center: a drive box and a host box joined by four lanes, two solid teal and two dashed and idle. Right: a vertical temperature scale with three marks and a copper band between the upper two.GUIDE / HOW STORAGE WORKS, PART 4PCIe Gen6 for storageFLIT · LANES · HEAT01 FLIT02 LANES03 HEAT

This part of How Storage Works takes up the storage layer those two leave out, from the flit to the power and heat limits a drive is built to and the first Gen6 drives. Where the SSD sits among the other tiers is the job of the memory and storage hierarchy, which opens the series.

Why Gen6 changed the signal

Through Gen5, PCIe sent one bit per symbol on two signal levels, called NRZ (non-return-to-zero), and Gen6 doubles the rate to 64.0GT/s with PAM4 (four-level pulse amplitude modulation), four levels and two bits per symbol, which leaves less room between levels for noise. Part 10 follows that signal in detail.

For a drive, the smaller margin shows up first as link error correction that earlier generations did without, which the next two sections cover. PCI-SIG’s design targets hold channel reach similar to PCIe 5.0 with at most two retimers, chips that re-drive the signal partway along the board, so the margin had to come from the link’s design and not from shorter traces. Part 10 gives the tighter channel-loss budget PCI-SIG set alongside that reach.

Why Gen6 changed the signal

PAM4 stacks three small eyes where NRZ has one

Same amplitude, two bits per symbol instead of one

Two panels. The left panel, NRZ, shows two horizontal levels with one tall eye between them spanning the full amplitude. The right panel, PAM4, shows four horizontal levels with three stacked eyes, each one third of the full amplitude. Under the panels, Gen5 runs at 32.0GT/s and Gen6 at 64.0GT/s.01 NRZ, GEN3 TO GEN502 PAM4, GEN6one eyetwo levelsone bit per symbolone thirdfour levelstwo bits per symbolGen5, 32.0GT/sGen6, 64.0GT/seye openingsignal level
Figure 4.1 · NRZ separates two levels with one wide eye. PAM4 separates four levels with three eyes, each one third of the full amplitude, so the link carries more data at the cost of noise margin. Eye shapes are drawn to that ratio, not measured. Source: PCI-SIG PCIe 6.0 FAQ; EDN, PAM4 basics.

PCI-SIG settled on a 256-byte flit with 236 bytes of transaction layer packet (TLP) payload and a TLP efficiency of 92%. A TLP is the packet PCIe uses for a memory read, a memory write or a completion, which is how an SSD fetches commands and moves data. PCI-SIG’s HOT Interconnects deck splits the remaining bytes into 6 of data link layer payload, 8 of CRC and 6 of FEC. One TLP can span several flits, and one flit can hold several TLPs.

The flit and what it costs an x4 link

A 256-byte flit carries 236 bytes of payload

Payload efficiency of 92% leaves about 30GB/s of an x4 link

Top, a horizontal bar for a 256-byte flit drawn to scale: 236 bytes of TLP payload in teal, then three thin copper fields for 6 bytes of data link layer payload, 8 bytes of CRC and 6 bytes of FEC. Middle, two bars for an x4 link: 32GB/s each way before framing and about 30GB/s after. Bottom, two cards comparing the chosen 256-byte flit at 92% efficiency with a 740-byte flit at about 97% that PCI-SIG dropped because it would have tripled latency, 16ns more on an x4 link.01 ONE FLIT, 256 BYTES236 bytes of TLP payload6 bytes DLP8 bytes CRC6 bytes FEC02 AN X4 LINK, EACH DIRECTION32GB/s before framingabout 30GB/s after framing03 WHY NOT A LONGER FLIT256-byte flit92% TLP efficiencychosen740-byte flitabout 97%, three times thelatency, 16ns more on x4TLP payloadlink fieldsbefore framing
Figure 4.2 · The flit bar is drawn to scale. The x4 bars show 32GB/s each way before framing and about 30GB/s after, an estimate from the 92% payload share. PCI-SIG rejected the larger flit for its latency. Source: PCI-SIG flit Q&A and HOT Interconnects deck; PCI-SIG PCIe 6.0 FAQ.

Framing sets what an x4 link delivers. A Gen6 x16 link reaches up to 256.0GB/s counting both directions, which works out to 32GB/s each way on an x4 link before framing. At 92% that leaves about 30GB/s, an estimate from those two figures, and Part 1 sets that limit beside drive speeds.

PCI-SIG also tested a 740-byte flit with 720 bytes of payload and about 97% efficiency. It dropped the larger flit because waiting for it to fill would have tripled the latency, adding 16ns on an x4 link.

Errors at a millionth: FEC, CRC and replay

PAM4’s smaller eyes raise the raw bit error rate (BER), and flit mode is built for the BER expected with PAM4, 10⁻⁶, against 10⁻¹² for NRZ in earlier generations. At 10⁻⁶ a link would see a raw bit error about every million bits, so correction has to be part of the link.

Each flit carries a CRC and a 3-way interleaved FEC. Receivers decode the FEC first, which corrects any correctable error within each FEC group, and then check the CRC. Any flit that still fails the CRC draws a NAK (negative acknowledgment) back to the transmitter, which replays it. Every flit has a dedicated slot to acknowledge or NAK the flit received.

Errors at a millionth: FEC, CRC and replay

A flit that fails its CRC check is replayed

FEC corrects first, the CRC decides, and a NAK triggers the replay

A flow in two rows. Top row, left to right: the transmitter sends a 256-byte flit, FEC decode fixes errors in each of three groups, the CRC check passes or fails the flit, and on a pass the TLPs are delivered to the NVMe layer. Below the CRC check, a copper arrow labeled fail leads to a NAK box, which points left to a replay box, which points up to the transmitter. A bottom panel compares the raw bit error rate of 10 to the minus 6 for PAM4 with 10 to the minus 12 for NRZ in earlier generations.Transmittersends one256-byte flitFEC decodefixes errors in3 FEC groupsCRC checkpass or failfor the flitTLPs deliveredto theNVMe layerNAKreturned totransmitterReplaysends theflit againfailresendRAW BIT ERROR RATE BEFORE CORRECTIONNRZ, earlier generations10-12PAM4, Gen610-6normal pathretry path
Figure 4.3 · Each flit carries a CRC and a 3-way interleaved FEC. The receiver decodes the FEC, then checks the CRC; a flit that still fails draws a NAK and the transmitter replays it. The raw bit error rates are what PAM4 expects against NRZ. Source: PCI-SIG flit Q&A and PCIe 6.0 FAQ.

PCI-SIG’s latency target for all of this is under 10ns added by the transmitter and receiver over 32.0GT/s, FEC included. Replay sits inside the link, below NVMe, so for a drive a retried flit should show up as added latency on that transfer and not as a failed command.

L0p, power that follows traffic

PCI-SIG’s deck lists L0s, L1, dynamic link width and speed change as the low-power states PCIe already had, and says demand has grown for power that scales with bandwidth use without interrupting traffic. L0p, new in PCIe 6.0, keeps at least one lane active, and the link keeps carrying traffic while its width changes.

L0p, power that follows traffic

L0p drops lanes but the link keeps carrying traffic

Power scales with bandwidth use without interrupting the link

Two rows, each with a drive box on the left and a host box on the right joined by four lane lines. In the first row all four lanes are solid teal with copper arrows. In the second row, labeled L0p, two lanes are solid teal and carry copper arrows and two are dashed and gray, marked as idle. A double-headed arrow between the rows reads width changes, traffic continues.01 FULL WIDTHDriveHostevery lane carries traffic02 L0P, NARROWEDDriveHostidle laneidle laneidle lanes powered down, link still livewidth changes, traffic continuesactive laneidle lanetraffic
Figure 4.4 · At full width every lane carries traffic. In L0p the link narrows, at least one lane stays active, and traffic continues through the width change. The number of lanes drawn is illustrative, not a specified width. Source: PCI-SIG HOT Interconnects deck; OCP Datacenter NVMe SSD Specification 2.7.

OCP’s Datacenter NVMe SSD Specification 2.7 makes it a drive requirement. Requirement PCI-42 reads, “For PCIe Gen6 devices, L0p shall be supported.” Gen6 drives built to that text can narrow their link while they keep serving reads.

The power and heat a Gen6 drive is held to

The same OCP specification sets power and heat limits for every drive built to it, whatever its PCIe generation; of the rules here, only PCI-42 is written for Gen6 alone. Max average power sets a drive’s burst allowance, and peak power is measured over a 100µs window. Drives at 25W or less may peak at no more than 1.5 times their average. From above 25W up to 29W the peak may be no more than 37.5W, which is 1.5 times 25W held flat, and above 29W the peak may be no more than 1.3 times the average. At idle, requirement PWR-6 asks for 5W or less whatever the form factor or capacity, reached automatically without hurting latency or performance.

The power and heat a Gen6 drive is held to

OCP holds peak power and temperature to fixed marks

Burst allowance by average power, and the three throttle marks

Top, a line chart. The horizontal axis is max average power in watts with marks at 25W and 29W; the vertical axis is peak power allowed in watts with a mark at 37.5W. A line rises at 1.5 times the average to 25W, runs flat at 37.5W until 29W, then rises more gently at 1.3 times. A note says idle power must be 5W or less. Bottom, a temperature scale with a mark at 75°C where throttling ends, 77°C where throttling starts, and 85°C where a critical component makes the drive report 85°C before it shuts off to protect itself.Peak power allowed, WMax average power, W37.5025291.5 times averagecapped1.3 times averageidle: 5W or less75°C77°C85°Cthrottling ends belowthrottling startsreports criticalComposite temperature, °Cscaled with averageflat capthrottling
Figure 4.5 · Top, the peak power OCP allows against max average power: 1.5 times up to 25W, flat at 37.5W to 29W, then 1.3 times. Bottom, throttling starts at 77°C, ends below 75°C, and a critical component makes the drive report 85°C. Axis ends carry no values. Source: OCP Datacenter NVMe SSD Specification 2.7, PCM-3, PWR-6, TTHROTTLE-5, -7 and -8.

Heat has three marks. A composite temperature of 77°C starts throttling, and the drive leaves throttling once it falls below 75°C. Once any component reaches a critical temperature, the drive reports 85°C and sends the host an event before it shuts off to protect itself. Those are requirements TTHROTTLE-5, -7 and -8, so the 85°C report is the drive’s last message before it shuts off.

The first Gen6 drives and controllers

Quarch judges it quite likely that the SFF-8639 connector behind U.2 and U.3 will not go to Gen6, the case Part 10 makes in full. The Gen6 drives below whose makers state a form factor use EDSFF (Enterprise and Data Center Standard Form Factor): Micron’s 9650 in E1.S and E3.S, and Kioxia’s GP1 in E3.S and E1.S 9.5mm. OCP 2.7 writes its Gen6 form factor rule into its E3 section, requirement FFE3-6, which has 64GT/s devices follow PCI Express Base Specification revision 6.2 or later. Part 1 covers the bays themselves, and its section on what is on offer places these drives among the rest.

The first Gen6 drives and controllers

First Gen6 ratings sit just under what an x4 link leaves

Maker-rated sequential speed against an estimate of the link

Horizontal bars in gigabytes per second. An estimate of about 30 for an x4 Gen6 link after framing is drawn hollow with a dashed copper edge. The Micron 9650 is rated 28 for sequential read, the Samsung PM1763 16TB 28.4 for sequential read, and the FADU Sierra FC6161 controller 28.5 for sequential read and write. The three maker bars are teal and nearly as long as the estimate.Part and what is rated010203040Sequential speed, GB/sGen6 x4 after framingestimateabout 30Micron 9650sequential read28Samsung PM1763 16TBsequential read28.4FADU Sierra FC6161controller, read and write28.5maker ratingestimate
Figure 4.6 · Maker ratings measured under different conditions, one of them a controller, so they mark where the link ends and not which part is faster. The hollow bar is an estimate from 32GB/s each way and a 92% payload share. Source: Micron 9650 brief; Samsung PM1763 release; FADU Sierra release; PCI-SIG flit Q&A and PCIe 6.0 FAQ.

Micron’s 9650 is rated up to 28GB/s sequential read and more than 5.5 million random read IOPS, and Micron’s blog calls it the first Gen6 SSD in mass production. Micron’s own 1,120MB/s per watt figure divides the 28GB/s rating by 25W, so it assumes a 25W draw. The brief also lists sequential read power of up to 18W for the 9650 PRO and MAX, and supports liquid cooling in E1.S 9.5mm.

Samsung announced mass production of the PM1763 on July 8, 2026. Its 16TB model is rated up to 28,400MB/s sequential read, Samsung puts the power efficiency at more than 1.8 times its predecessor’s, and the drive is optimized for direct-to-chip liquid cooling. FADU unveiled its Sierra (FC6161) controller in August 2025 with up to 28.5GB/s sequential read and write and a power envelope below 9W. Kioxia’s GP1, announced August 3, 2026, is a PCIe 6.0 NVMe 2.2 SSD rated up to 10 million random read IOPS at 512 bytes, with cold-plate liquid cooling in E3.S and E1.S 9.5mm. Liquid cooling is not a Gen6 feature alone: in October 2026 Kioxia added E3.S direct liquid cooling models to its PCIe 5.0 CM9 series. Part 10 covers the other Gen6 controllers announced so far, Marvell’s Bravera SC6 and Phison’s X3.

Sequential ratings of 28 to 28.5GB/s sit just under the roughly 30GB/s an x4 link leaves after framing. They come from makers under different conditions, and FADU’s is a controller rating, so they show that the link is now the limit for sequential reads, not which drive is faster. The two IOPS ratings on this page use different block sizes, so they do not rank the drives either.

PCI-SIG keeps PCIe 6.0 backward compatible with every earlier generation, so a Gen6 drive also works in an older slot, but it needs a Gen6 host to run at Gen6. On the host side, AMD announced on July 23, 2026 that its 6th Gen EPYC 9006 server CPUs, code-named Venice, bring PCIe Gen6, and StorageReview reports that Venice platforms come in waves, with SP7 expected in the fourth quarter of 2026 and SP8 in the first half of 2027.

Gen7, and the Gen8 draft

PCIe 7.0 runs at 128.0GT/s, double the 64.0GT/s of PCIe 6.x, and PCI-SIG released the specification to members on June 11, 2025, rated at up to 512GB/s counting both directions on an x16 link. Its draft 0.5 of PCIe 8.0 targets 256.0GT/s and up to 1.0TB/s bidirectionally on an x16 link, with full release on track for 2028. As of November 2026 these are specifications and drafts, and every drive above runs Gen6.

Gen7, and the Gen8 draft

Each generation doubles the raw rate, and Gen8 is a draft

Raw bit rate per lane, PCIe 5.0 through the PCIe 8.0 draft

Vertical bars of raw bit rate per lane in gigatransfers per second. PCIe 5.0 is 32.0, PCIe 6.0 is 64.0, PCIe 7.0 is 128.0 and was released to members on June 11, 2025, and PCIe 8.0 is 256.0 in draft 0.5, on track for 2028, drawn dashed and hollow.Raw bit rate per lane, GT/s06412819225632.0PCIe 5.064.0PCIe 6.0128.0PCIe 7.0to membersJune 11, 2025256.0PCIe 8.0draft 0.5on track 2028PCIe specification and statusreleaseddraft
Figure 4.7 · PCIe 7.0 was released to PCI-SIG members; PCIe 8.0 is at draft 0.5, targeting full release by 2028 according to PCI-SIG, so its bar is dashed. Source: PCI-SIG PCIe 7.0 page, PCIe 6.0 FAQ and PCIe 8.0 draft 0.5 blog.

Gen7’s target for SSDs comes from the GPU side. StorageReview reports that NVIDIA’s Storage-Next roadmap calls for PCIe Gen7 SSDs sustaining 100 million IOPS each, a target that controller vendors including Marvell are designing toward. Kioxia’s GP1 rates 10 million at a 512-byte block size, and the report’s sentence gives no block size for the 100 million, so the two are not yet a like-for-like gap.

Two things to look for next are a controller datasheet that lists a 128.0GT/s interface, and an OCP revision that adds Gen7 rules the way version 2.7 adds PCI-42 for Gen6. Part 5 of the series moves from the link to the host’s side of the drive, with zoned namespaces (ZNS) and flexible data placement (FDP), and the series page lists every part.