Drives that lost data, stopped working after a set number of hours, crashed the computer, dropped off it or slowed down, each taken from the advisory the drive’s own seller published, with the fixed firmware where the seller names one. Ranked by what the seller says happens, worst first, and not by anyone’s guess at how many drives were hit.

How to read it

8 of these advisories tie the failure to a count of power-on hours, the time a drive has spent switched on: once a drive has run that long on the old firmware, it fails. HPE’s advisory puts the soonest at 4,700 power-on hours, which is 195 days, 20 hours of running without a break. Cisco, Dell and HPE each published an advisory for drives that fail at 40,000 hours, 4 years, 206 days, 16 hours, which Cisco rounds to 4.5 years.

The board ranks by harm first, in an order we chose: loses data, drive stops working, crashes the computer, drops off the computer and slows down. A row’s harm follows the seller’s own words, so two advisories can describe the same symptom and still sit in different tiers: Cisco and Dell both say the drive reports 0 GB and goes offline, but only Cisco says data is lost. Inside a harm, a defect with an hour count ranks ahead of one without, fewest hours first, since a drive that fails sooner leaves less time to update it.

Hours until the drive fails8 advisories

Only the advisories that give an hour count. Tap a bar to jump to its row.

Power-on hours until the drive fails

  • Loses data
  • Drive stops working
  • Drops off the computer
  • Each year of running day and night
010,00020,00030,00040,00050,00060,00070,0001 yr2 yr3 yr4 yr5 yr6 yr7 yrPower-on hours at failure, as the advisory statesHPE, Certain HPE NVMe SSD models: fails at 4,700 power-on hours, 195 days, 20 hours; loses dataHPE, fixed by 4ICRHPK34,700Cisco, Micron M500IT SATA SSD in Cisco UCS 6324 and 6332 fabric interconnects: fails at 28,224 power-on hours, 3 years, 81 days; drops off the computerCisco, fixed by CZ03 +228,224Cisco, Micron M500IT SATA SSD in Cisco Nexus 9000 and 3000 switches: fails at 28,224 power-on hours, 3 years, 81 days; drops off the computerCisco, fixed by MC03, MU0528,224HPE, Certain HPE SAS SSD models: fails at 32,768 power-on hours, 3 years, 270 days, 8 hours; loses dataHPE, fixed by HPD832,768Cisco, Certain Cisco UCS SAS SSD models: fails at 40,000 power-on hours, 4 years, 206 days, 16 hours; loses dataCisco, fixed by C40540,000HPE, Certain HPE SAS SSD models: fails at 40,000 power-on hours, 4 years, 206 days, 16 hours; loses dataHPE, fixed by HPD740,000Dell, Dell Enterprise SAS SSDs LT0200MO to LT0800WM, 9 models: fails at 40,000 power-on hours, 4 years, 206 days, 16 hours; drive stops workingDell, fixed by D41740,000HPE, Certain HPE SAS hard drives, 4 TB to 14 TB: fails at 65,536 power-on hours, 7 years, 175 days, 16 hours; loses dataHPE, fixed by HPD3 +365,536HPE, Certain HPE SATA hard drives, 4 TB to 14 TB: fails at 65,536 power-on hours, 7 years, 175 days, 16 hours; loses dataHPE, fixed by HPG4 +365,536Dell, Dell Toshiba PM2, PM2+ and PM2R SAS SSDs, 9 part numbers: fails at 70,000 power-on hours, 7 years, 361 days, 16 hours; drive stops workingDell, fixed by A3B4 +270,000
Linear scale from zero. Each bar is the hour count a seller’s advisory gives for the failure; the dotted lines mark 365-day years of running without a break. Advisories that give no hour count, or that say the drive only slows down, are on the board below, not on this chart.

The board23 rows

Ranked by harm, then by hours to failure. Tap a heading to sort by it, or filter by seller and interface.

RankSellerDrivesInterfaceWhat happensAt power-on hoursIn the seller’s words, our summaryFixed firmwareSeller source
1HPECertain HPE NVMe SSD modelsNVMeLoses data4,700
195 days, 20 hours
The drive fails at that hour count, and HPE says neither the drive nor its data can be recovered.4ICRHPK3HPE customer bulletin
2HPECertain HPE SAS SSD modelsSASLoses data32,768
3 years, 270 days, 8 hours
The drive fails at that hour count, and HPE says the data on it is lost.HPD8HPE SAS SSD remediation guide
3CiscoCertain Cisco UCS SAS SSD modelsSASLoses data40,000
4 years, 206 days, 16 hours
The drive reports 0 GB of storage, goes offline and becomes unusable, and Cisco says data is lost.C405Cisco field notice FN70545
3HPECertain HPE SAS SSD modelsSASLoses data40,000
4 years, 206 days, 16 hours
The drive fails at that hour count, and HPE says the data on it is lost. HPE says the defect is not unique to HPE.HPD7HPE SAS SSD remediation guide
5HPECertain HPE SAS hard drives, 4 TB to 14 TBSASLoses data65,536
7 years, 175 days, 16 hours
The hard drive fails at that hour count and cannot be recovered, and HPE warns of data loss.HPD3, HPD4, HPD5, HPD7HPE customer bulletin
5HPECertain HPE SATA hard drives, 4 TB to 14 TBSATALoses data65,536
7 years, 175 days, 16 hours
The hard drive fails at that hour count and cannot be recovered, and HPE warns of data loss.HPG4, HPG5, HPG6, HPG8HPE customer bulletin
7DellDell Intel S4510 and S4610 SSDs, 1.92 TB and 3.84 TBSATALoses datanot statedThe drive can stop answering the host or fail early, and after a power cycle Dell says its data cannot be recovered.DL63, XCV10110Dell knowledge base article
8LenovoKioxia BG5 SSDs in ThinkPad, ThinkCentre and ideacentre PCsNVMeLoses datanot statedLarge installs or file copies can hang the PC, then the drive is never detected again and its data is lost.1107ANLALenovo support article
9DellDell Enterprise SAS SSDs LT0200MO to LT0800WM, 9 modelsSASDrive stops working40,000
4 years, 206 days, 16 hours
The drive reports 0 GB of storage, goes offline and cannot be used after a power cycle.D417Dell knowledge base article
10DellDell Toshiba PM2, PM2+ and PM2R SAS SSDs, 9 part numbersSASDrive stops working70,000
7 years, 361 days, 16 hours
The drive locks after a power cycle, takes no reads or writes and shows as 0 GB, and a firmware update unlocks it.A3B4, A4B4, A5B4Dell knowledge base article
11DellDell Enterprise Intel SATA SSDs, 20 part numbers from 240 GB to 7.6 TBSATADrive stops workingnot statedThe drive may fail early, and the server may show it as failed or missing.DL7ADell knowledge base article
12DellMicron 7450 and 7500 NVMe SSDs sold by DellNVMeDrive stops workingnot statedThe drive may fail to initialize, and Dell says a drive that hits this cannot be recovered.E2MU300, E3MQ005Dell knowledge base article
13DellSamsung PM883a SATA SSDs sold by DellSATADrive stops workingnot statedIn rare cases the drive reports ERRORMOD and 0 GB, and the failed drive may become inaccessible.HG58Dell knowledge base article
14LenovoThinkSystem Samsung PM1653 and PM1655 SAS SSDs on firmware CA00SASDrive stops workingnot statedGarbage collection falls behind, the drive times out, and a RAID controller marks it failed for good.CA01Lenovo technical tip
15HPEHPE NVMe SSDs on firmware MPK77H5Q, MPK7725Q or HPK5NVMeCrashes the computernot statedThe drive may cause an uncorrectable machine check exception on HPE Gen9 to Gen11 servers.MPK7825Q, MPK78H5Q, HPK6HPE customer advisory
16Sandisk2 TB WD_BLACK SN770 and SN770M, WD Blue SN580 and SN5000, SANDISK Extreme M.2NVMeCrashes the computernot statedA Host Memory Buffer issue may crash Windows 11 24H2 with a blue screen, and Microsoft may hold back the 24H2 upgrade until the drive is updated.731130WD, 281050WD, 291020WDSandisk support article
17CiscoMicron M500IT SATA SSD in Cisco UCS 6324 and 6332 fabric interconnectsSATADrops off the computer28,224
3 years, 81 days
The drive becomes unresponsive until a power cycle, and Cisco says no data is lost.CZ03, MC03, MU05Cisco field notice FN72028
17CiscoMicron M500IT SATA SSD in Cisco Nexus 9000 and 3000 switchesSATADrops off the computer28,224
3 years, 81 days
The drive stops responding and the switch bootflash goes read-only, and it comes back after a power cycle for about six more weeks.MC03, MU05Cisco field notice FN72150
19HPECertain HPE NVMe SSD modelsNVMeDrops off the computernot statedAfter resets the drive may show as 0 GB and stay undetected until the host is rebooted or power cycled.EPK76H3Q, MPK76H5Q, MPK7625Q, HPK6HPE customer advisory
20LenovoThinkSystem M.2 Micron 7450 PRO 480 GB and 960 GB on firmware E2MU300NVMeDrops off the computernot statedAfter under 1% of power cycles the server logs the drive as faulted and its RAID volume can go offline until the next power cycle.not namedLenovo technical tip
21LenovoThinkSystem Solidigm S4520 7.68 TB SATA SSDsSATADrops off the computernot statedAfter a warm reboot from ESXi the drive may not be seen by the server controller, UEFI or ESXi.not namedLenovo technical tip
22SandiskSANDISK Extreme and Extreme PRO Portable SSD, WD My Passport SSD, made before 2023USBDrops off the computernot statedSome drives unexpectedly disconnect from the computer. Sandisk says to back up and verify data before updating.not namedSandisk support article
23DellMicron 5100 and 5200 SATA SSDs sold by DellSATASlows down65,535
7 years, 175 days, 15 hours
A 16-bit log counter tops out and the drive floods its own debug log, so reads and writes slow; Dell says no data is lost.L013, F006Dell knowledge base article

What it will not tell you

It does not tell you how many drives failed. No advisory here gives a count, so the board ranks by what the seller says happens, which is a ranking of harm and not of how widespread a defect was. Cisco, Dell and HPE each give 40,000 hours, and Cisco and Dell describe the same symptom. HPE says its defect came from an SSD supplier and is not unique to HPE, but none of these pages says whether the three are one part.

A seller on this board is the one that published the advisory, which is not always the company that made the drive or wrote its firmware. The board holds only defects whose seller still publishes its own advisory, so failures known only from forums, news stories or a seller page that is gone are left out, however well known they are. The update protects a drive that has not reached the defect yet; Cisco says a drive that already reached 40,000 hours is unusable and must be replaced. Each row links the seller’s page it was read from on November 3, 2026.