Benchmarking 201

SSD Benchmarking 201, Part 5: One Controller at Three Capacities

My Iometer runs on one enterprise SSD design at 480GB, 960GB and 1,920GB, and what capacity changes in random writes, deep-queue reads and sequential speed.

On this page 5 sections

Part 4 of this series set published reviews beside my own runs and found that a result only transfers when the job behind it matches. Capacity has to match too. An enterprise SSD line usually offers several capacities on one controller, and a review tests one or two of them. In July 2022 I ran the same Iometer job on an E18DC-based enterprise NVMe engineering sample at 480GB, 960GB and 1,920GB, so capacity is the only thing that changes from one set of numbers to the next.

One enterprise SSD design tested at three capacities with the same Iometer jobA three-panel cover. Left: one job file listing its settings, transfer size, read share, randomness, the queue depths from QD1 to QD256, and a note that it runs the same at each size. Center: three drive outlines of one design labeled 480GB, 960GB and 1,920GB, with the flash area filling more of each board as the capacity grows. Right: a queue depth axis where three read curves, one per capacity, start from one shared copper point at QD1, marked same, and fan apart toward QD256, marked apart.GUIDE / BENCHMARKING 201, PART 5One controller, three capacitiesJOB FILE · CAPACITY · RESULT01 ONE JOB02 CAPACITY03 READSsize 4KiBreads 0 to 100%random 100%QD1 to QD256same at each size480GB960GB1,920GBsameapartQD1QD256

At queue depth (QD) 1, reads ran the same at every capacity. Writes and deep-queue reads grew with it, by close to double from 480GB to 960GB and by about a third again from 960GB to 1,920GB. Every result here is mine, recomputed from the raw Iometer rows of each run. I name the sample by its controller and capacity only. It ran on a different test system from the older drives in Part 3, so its numbers stay apart from theirs.

The same job at three capacities

Each capacity got the same steps. A 3h 4KiB random write precondition at QD256, with 16 workers x 16 outstanding I/Os, left the drive written over before anything was measured. After it came the same 4KiB sweep that Part 1 describes for this sample, 11 read shares at each of 9 queue depths. A 128KiB sequential precondition and sweep ran separately. QD here is the total number of I/Os in flight, as in Part 1.

Phison’s E18DI datasheet, for the industrial version of the E18 family, lists up to 8 NAND channels with 32 chip enables behind a PCIe 4.0 x4 link. A bigger capacity on the same controller puts more flash dies behind those channels. I don’t have this sample’s die count, so this page reads the results without one.

The Parallelism Lab models the same effect with die count and capacity you can set. The 3h preconditions already showed the split, with 4KiB random writes averaging 17,850 IOPS at 480GB, 36,474 at 960GB and 56,247 at 1,920GB.

The same job at three capacities

Each doubling of capacity raised the precondition’s write rate

E18DC-based engineering sample, 3h 4KiB random write precondition, QD256

A horizontal bar chart of the average 4KiB random write rate over a 3h precondition at queue depth 256, for one E18DC-based enterprise NVMe engineering sample at three capacities: 17,850 IOPS at 480GB, 36,474 IOPS at 960GB and 56,247 IOPS at 1,920GB.Capacity015,00030,00045,00060,000Average 4KiB random write IOPS over 3h, QD256480GB17,850960GB36,4741,920GB56,2473h precondition average
Figure 5.1 · The same 3h precondition averaged 17,850 IOPS at 480GB, 36,474 at 960GB and 56,247 at 1,920GB. Source: my enterprise test runs, Iometer 1.1.0, July 2022, 16 workers × 16 outstanding I/Os, recomputed from the raw Iometer rows.

QD1 reads didn’t change with capacity

A 4KiB random read at QD1 waits on one die to sense its page and send it over one channel. With nothing else in flight, extra dies have no second read to work on, however many a drive has. The sample ran 13,095 IOPS at 480GB, 13,319 at 960GB and 13,078 at 1,920GB, each at an average response time of 0.075 to 0.076ms.

Capacity starts to count once more reads are waiting. At QD4 the three were still within 10% of each other, at 45,957, 49,301 and 50,448 IOPS. By QD32 the 1,920GB drive ran 263,839 IOPS, 1.99 times the 480GB drive’s 132,340. By QD256 the three reached 264,124, 496,209 and 646,007 IOPS.

QD1 reads didn’t change with capacity

The three capacities read alike at QD1 and split apart with depth

E18DC-based engineering sample, 4KiB random reads after the 3h write precondition

A line chart of 4KiB random read IOPS at queue depths 1, 4, 32 and 256 for one E18DC-based enterprise NVMe engineering sample at three capacities. At QD1 the three sit together at 13,095, 13,319 and 13,078 IOPS for 480GB, 960GB and 1,920GB. At QD4 they are 45,957, 49,301 and 50,448. At QD32 they spread to 132,340, 199,617 and 263,839, and at QD256 to 264,124, 496,209 and 646,007.4KiB random read IOPS0175,000350,000525,000700,000QD1QD4QD32QD256Queue depth (total I/Os in flight)480GB960GB1,920GB
Figure 5.2 · At QD1 all three ran 13,078 to 13,319 IOPS; by QD256 the 1,920GB drive ran 646,007 against 264,124 at 480GB. Source: my enterprise test runs, Iometer 1.1.0, July 2022, one step per queue depth, recomputed from the raw Iometer rows.

With more reads waiting, a controller can keep several dies busy at once, which is the interleaving that Agrawal and co-authors show lets reads and writes on independent dies overlap. Flash Foundations, Part 5 covers how channels and dies split that work. An average QD256 read took 0.969ms at 480GB and 0.396ms at 1,920GB, most likely because each read queued behind fewer others on its die.

Random writes followed capacity, not queue depth

After the precondition, 4KiB random writes hardly moved with depth at any capacity. The 480GB drive ran 17,825 IOPS at QD1 and 18,440 at QD256, the 960GB drive 35,337 and 36,046, and the 1,920GB drive 48,271 and 48,522.

On a drive the precondition has written over, new writes most likely share the dies with the controller’s own cleanup of old blocks. More I/Os in flight don’t add dies, so they didn’t add write speed, but more capacity did. From 480GB to 960GB the QD256 rate rose 1.95 times, and from 960GB to 1,920GB it rose 1.35 times.

Extra depth turned into waiting instead, and at QD256 an average 4KiB write took 13.882ms at 480GB, 7.102ms at 960GB and 5.276ms at 1,920GB. A job that piles on depth to find a drive’s write speed mostly measures how long its queue is.

Random writes followed capacity, not queue depth

More capacity raised random writes and shortened every write’s wait

E18DC-based engineering sample, 4KiB random writes at QD256 after the 3h precondition

A vertical bar chart of 4KiB random write IOPS at queue depth 256 for one E18DC-based enterprise NVMe engineering sample at three capacities, with the average response time over each bar: 18,440 IOPS at 13.882 milliseconds for 480GB, 36,046 IOPS at 7.102 milliseconds for 960GB and 48,522 IOPS at 5.276 milliseconds for 1,920GB.4KiB random write IOPS at QD256, thousands01530456013.882ms avg18,440480GB7.102ms avg36,046960GB5.276ms avg48,5221,920GBCapacity4KiB random writes, QD256, with average response time
Figure 5.3 · The 1,920GB drive wrote 48,522 IOPS at 5.276ms on average, the 480GB drive 18,440 at 13.882ms. Source: my enterprise test runs, Iometer 1.1.0, July 2022, 16 workers × 16 outstanding I/Os, recomputed from the raw Iometer rows.

Mixed loads follow the writes, and at 70% reads and QD256 the sample ran 54,110 IOPS at 480GB, 102,365 at 960GB and 136,659 at 1,920GB. Its writes kept each capacity far below its all-read result, as Part 3 showed for the 1,920GB drive across the whole read mix.

Sequential writes doubled with each capacity step

128KiB sequential writes held one rate at every depth from QD1 to QD256. They ran 368.1 to 369.3MB/s at 480GB, 784.7 to 788.1MB/s at 960GB and 1,600.8 to 1,605.8MB/s at 1,920GB. Each step up in capacity doubled the rate, 2.12 times and then 2.04 times at QD256. Once a drive is writing at its sustained rate, a queue gives it nothing more to do.

Sequential reads ran into a different limit. The 480GB drive peaked at 4,169.4MB/s at QD128. The 960GB and 1,920GB drives both peaked above 7GB/s, at 7,149.4MB/s and 7,118.4MB/s, close to the 7.9GB/s a PCIe 4.0 x4 link carries in each direction. At 960GB and 1,920GB the host link was most likely the limit, not the flash. At QD1 all three read 128KiB blocks at 1,232.3 to 1,345.7MB/s, with the 1,920GB drive the slowest.

Sequential writes doubled with each capacity step

Sequential writes doubled per capacity step and reads hit the link

E18DC-based engineering sample, 128KiB sequential, writes at QD256, reads at their QD128 peak

A vertical bar chart of 128KiB sequential MB/s for one E18DC-based enterprise NVMe engineering sample at three capacities, a write bar and a read bar for each. Writes at queue depth 256: 369.3MB/s at 480GB, 784.7 at 960GB and 1,602.4 at 1,920GB. Peak reads at queue depth 128: 4,169.4MB/s at 480GB, 7,149.4 at 960GB and 7,118.4 at 1,920GB. A dashed line at 7.9GB/s marks what a PCIe 4.0 x4 link carries in each direction.128KiB sequential MB/s02000400060008000369.3480GBwrite4,169.4480GBread784.7960GBwrite7,149.4960GBread1,602.41,920GBwrite7,118.41,920GBreadCapacity and directionWrite, QD256Read, peak at QD128PCIe 4.0 x4, about 7.9GB/s
Figure 5.4 · Writes ran 369.3, 784.7 and 1,602.4MB/s; reads peaked at 4,169.4MB/s at 480GB and above 7GB/s at both larger capacities, under the 7.9GB/s a PCIe 4.0 x4 link carries. Source: my enterprise test runs, Iometer 1.1.0, July 2022, recomputed from the raw Iometer rows; link rate for PCIe 4.0 x4 after 128b/130b encoding.

What one capacity tells you about another

A result belongs to the capacity it was measured on. On this design, a review of the 1,920GB model would overstate the 480GB model’s random writes 2.63 times, its deep-queue random reads 2.45 times and its sequential writes 4.34 times, while getting its QD1 reads right. Sequential reads would transfer down to 960GB and no further.

What one capacity tells you about another

The largest capacity’s results overstate the smallest by up to 4.34×

E18DC-based engineering sample, 1,920GB result divided by 480GB result

A horizontal bar chart of how many times the 1,920GB drive's result is the 480GB drive's for four tests on one E18DC-based enterprise NVMe engineering sample: 1.00 times for 4KiB random reads at QD1, 2.45 times for 4KiB random reads at QD256, 2.63 times for 4KiB random writes at QD256 and 4.34 times for 128KiB sequential writes. A dashed mark at 1 time shows no change.Test0123451,920GB result ÷ 480GB result4KiB random read, QD11.00×4KiB random read, QD2562.45×4KiB random write, QD2562.63×128KiB sequential write4.34×1,920GB ÷ 480GBSame result (1×)
Figure 5.5 · QD1 reads came out the same at 480GB and 1,920GB, while deep-queue reads, random writes and sequential writes did not carry over. Source: my enterprise test runs, Iometer 1.1.0, July 2022; ratios worked out from the raw Iometer rows.

Read any enterprise review’s write and deep-queue numbers as describing its capacity only, since light, low-depth reads were the one result that carried across all three sizes here. Before trusting a chart of the largest model, check which capacity the review tested, and test or find results for the capacity you plan to buy. That puts capacity on the list of settings a fair comparison has to match, next to the job, the drive’s state and the host.