SC26: Expensive Memory and the Argument Over Where Data Goes

What SC26’s sessions said about memory and storage, from the recordings: DRAM and flash prices that kept climbing, models that outgrew the GPU, CXL as a second life for old DIMMs, the fight over keeping or recomputing the KV cache, drives chasing 100M IOPS, and the power every gigabyte per second of storage bandwidth costs.

On this page 13 sections

Anil Godbole of Intel and the CXL Consortium told SC26’s panel on Compute Express Link (CXL) memory that a DDR5 DIMM has gone up fourfold in price. By the end of the week I’d heard the same complaint in the TOP500 session, a memory workshop, a DAOS update, a unified-memory session and a storage tutorial. Speaker after speaker said memory was short and costly, and the models keep asking for more of it. So most of what SC26 said about memory and storage came down to one argument. Once data no longer fits beside the GPU, where should it go, and when is it cheaper to throw it away and compute it again?

The three kinds of memory SC26 argued over: HBM beside the GPU, a DDR5 DIMM and an M.2 SSDThree numbered panels. HBM: a cross-section of an HBM stack, a base die under eight core dies joined by through-silicon vias, beside a compute die, both on a silicon interposer over the package substrate. DRAM: the front of a DDR5 module with 144 gold contacts, a keyed edge, eight memory packages in two groups of four and the power chip between its inductors. Flash: an M.2 2280 SSD board with its controller, DRAM and NAND packages and gold edge fingers.EVENT COVERAGE / SC26SC26: where memory and storage standHBM · DRAM · FLASH01 HBMBeside the GPU02 DRAMBehind the CPU03 FLASHIn the drive slot

SC26 ran at McCormick Place in Chicago from November 15 to 20, 2026. I went through every session on the program, then watched the recordings of the memory and storage sessions through an attendee login, along with the slides the speakers made public. A speaker’s number is that speaker’s claim, and a vendor’s benchmark is a test the vendor ran. Speakers agreed on the problem, and the CXL sessions agreed on reusing memory a site already owns. They didn’t agree on where the overflow should go, whether down the tiers our context memory guide lays out or into CXL memory, which sits beside that ladder rather than on it, and no session I watched tested the main candidates against each other. Announcements from the show floor get one section near the end.

Memory became the expensive part

Erich Strohmaier edits the TOP500, and he gave the price story its most official form. The 68th list had the same ten leaders as June, and he told the TOP500 session that part of the reason is that “prices have really gone up, in particular for memories and for accelerators.” A site that buys a new machine now may end up with less than it already has on the floor, he added, though “we don’t know the details.”

System builders were more specific. Godbole said a 128GB DIMM now costs more than four times a 64GB one, because the larger part needs denser chips. Michael Hennecke of HPE opened his DAOS update by saying “we hold a lot of our metadata in DRAM, which is really expensive,” and DAOS 2.8 now moves cold metadata to SSD. In the Optane era its persistent memory came to about 6% of the flash behind it, and without that memory the metadata share held in DRAM is below 1% today. AMD’s Austin Ellis told the unified memory birds-of-a-feather session that there has never been a better time for chips that share one pool of HBM between CPU and GPU, “just due to the procurement costs of memory.” DDN’s Chris Grossmeier put it more bluntly in the Taming AI Storage Systems tutorial: “Memory’s not cheap nowadays. SK Hynix and Micron are making a fortune off this, and we’re seeing backlogs for years.”

Memory became the expensive part

Speakers put NAND up about 10x, DRAM 4x and hard drives 2x

Price increases as the speakers stated them, with different timeframes

Horizontal bars of price increase as a multiple. NAND flash up by a factor of 10, per VDURA's Garth Gibson. Large SSDs up sevenfold in 12 months, per HPE's brief for its hybrid E2000. A DDR5 DIMM up fourfold, per the CXL Consortium's Anil Godbole. HDD up by a factor of two, per Gibson.Component0246810Price increase, multipleNAND flashGibson, about 18 months10xLarge SSDsHPE brief, 12 months7xDDR5 DIMMGodbole, no period stated4xHDDGibson, no period stated2xFlashOther media
Figure 1 · Price increases as SC26 speakers and one product brief stated them, over different periods; none is a measured index. Source: VDURA exhibitor talk and CXL panel, SC26, November 2026; HPE Cray E2000 solution brief; speakers' estimates.

Flash went the same way. VDURA’s Garth Gibson put NAND prices up by a factor of 10 in about a year and a half and hard drive prices up by a factor of two, and HPE’s brief for its hybrid Cray E2000 says large SSDs rose sevenfold in 12 months. DDN’s Irfan Ahmad told the storage panel that every customer is now asking for hard drives because QLC prices rose. Penguin Solutions has started harvesting and reconditioning old DDR4 so customers can put it behind CXL.

Nobody in these rooms expected relief soon. Godbole relayed that memory makers expect supply to be good again starting maybe 2028, and until then the price sets the terms for everything below it. A site can’t buy its way out of a shortage, so it has to decide which data earns a place in the memory it can afford.

Models want more memory than a GPU holds

NVIDIA’s Vikram Mailthody brought the week’s clearest data on demand to the Emerging Storage Technology panel. His slides track open model releases year by year. In 2026 the median mixture-of-experts release stores 68 times the parameters of the median dense release while computing with only 3.3 times more. His slide drew the conclusion that memory capacity and arithmetic throughput have become separate provisioning problems. A GPU sized for the math now runs out of room long before it runs out of work.

The key-value (KV) cache, the memory a model keeps for each conversation, pulls the other way. Across 271 releases, the median KV cache per token has halved every year, and a 128K-token context that takes about 64.0GiB with multi-head attention takes less than a gigabyte with the compressed attention of 2026’s releases so far.

Models want more memory than a GPU holds

Models cut KV cache per token 78-fold by changing attention

Median open-model releases, bf16, from NVIDIA’s panel slides

Two charts. Left: gibibytes of KV cache for one 128K-token sequence, by attention family: multi-head attention 64.0, grouped or multi-query 16.0, multi-head latent attention 8.6, hybrid 3.1, compressed 0.8, a 78-fold drop from first to last. Right: share of releases by family. 2023: 70% multi-head, 30% grouped. 2024: 23% multi-head, 66% grouped, 6% latent, 4% hybrid. 2025: 3% multi-head, 66% grouped, 10% latent, 21% hybrid. 2026 so far: 29% grouped, 20% latent, 40% hybrid, 11% compressed.01 ONE 128K SEQUENCE02 SHARE OF RELEASESAttention family016324864MHA64.0GQA/MQA16.0MLA8.6Hybrid3.1Compressed0.8KV cache, GiBShare of releases, %02550751007030202323662024662120252920402026Release yearMHAGQA/MQAMLAHybridCompressed
Figure 2 · Left, KV cache for one 128K-token sequence by attention family; right, each family’s share of open-model releases by year, 2026 partial. Source: Vikram Mailthody, NVIDIA, Emerging Storage Technology panel slides, SC26, November 18, 2026; 271 releases through August 13, 2026.

Most of that drop came from changing the attention mechanism. Releases moved from multi-head attention to grouped-query attention, then to latent attention and hybrids, and 2026 brought the first compressed designs. Mailthody warned that context lengths are heading toward a million tokens, so the savings get spent. He also told a Micron questioner that capacity is becoming the dominant factor for agentic work, while memory latency hasn’t yet. SK hynix’s Fan Zhang put about half of a GPU’s HBM to model weights and about a third to KV cache, which leaves little room for either to grow.

Papers in the main program kept running into that limit. The Taiji paper on serving found that long contexts fill the decode GPUs’ HBM and cap their batch size, so they reached only 34% compute use. The BaGuaLu-2 team, training mixture-of-experts models on more than 10,000 GPUs, opened with “HBM is very expensive.”

Past the edge of HBM, everything is slower

When data spills out of HBM, the next tier is far away. NVIDIA’s Todd Evans sized the gap at the unified memory session by dividing each platform’s GPU memory bandwidth by its link to the CPU. On Grace Hopper the gap is about 4.5x, on Grace Blackwell it is 18x, and on Vera Rubin, with HBM4 at 22TB/s, it reaches 24.5x. Ahmad’s panel slides made the same point for I/O, with one PCIe 6.0 x16 link at about 0.12TB/s and one 800GbE port at about 0.1TB/s against several terabytes a second from GPU to HBM.

Past the edge of HBM, everything is slower

GPU memory outruns its link to the CPU, and falls off a cliff

Two SC26 measurements of what happens past the edge of HBM

Two bar charts. Left: GPU memory bandwidth divided by the CPU-GPU link, about 4.5 times on Grace Hopper, 18 times on Grace Blackwell and 24.5 times on Vera Rubin, which NVIDIA's Todd Evans said means placement matters more each generation. Right: on an H100, a pointer chase took 244 nanoseconds with GPU memory to spare and 4,000 nanoseconds once the working set no longer fit, about 16 times more.01 HBM OVER THE CPU LINKHBM bandwidth ÷ link, x05101520254.5xGraceHopper18xGraceBlackwell24.5xVeraRubinNVIDIA platform02 H100 WHEN MEMORY FILLSPointer chase, ns01,0002,0003,0004,000244nsRoom tospare4,000nsGPUfullGPU memory stateHBM multipleFits in HBMSpills past HBM
Figure 3 · Left, HBM bandwidth as a multiple of the CPU-GPU link on three NVIDIA platforms; right, one H100 pointer chase with GPU memory free and full. Source: Todd Evans, NVIDIA, Unified Shared Memory BoF; unified-memory talk, HMEM workshop; SC26, November 2026.

The right half of the figure shows what crossing that gap costs when software gets placement wrong. RIKEN’s One API, Five Memories talk at the HMEM workshop ran the same unified-memory code on five systems. A pointer chase on an H100 took 244ns while the data fit in GPU memory and 4,000ns once it did not, about 16 times slower. Grace Hopper and the MI300X slowed about eight times, while GB10 and the MI300A, which have one physical pool, stayed flat. On the MI300A, bandwidth stopped at 93GB/s for reasons the team could not explain. “A hint is really a bet on the platform,” the speaker said of the memory-placement hints CUDA offers.

RIKEN’s Satoshi Matsuoka put a power figure on the same wall at the gigawatt infrastructure panel. Memory bandwidth per watt, which governs decode, “only has increased by a factor of two in over seven, eight years,” he said, and with more efficient data movement “your gigawatt data center may become a several hundred megawatt data center.”

CXL is for memory a site already owns

CXL attaches extra DRAM to a server over PCIe, so it is the obvious first stop past the CPU’s own memory channels. All three experts on the CXL panel rated it about an eight out of ten for readiness. Penguin’s CTO Phil Pokorny was the most direct. “CXL is not some future technology. It’s available today,” he said, and described a server with two AMD EPYC 9005 CPUs and eight CXL cards that reaches 11TB of RAM. He also warned that many server slots sit behind a PCIe switch that blocks CXL, so buyers have to read the block diagrams, and that the products “were a lot more compelling when RAM was cheaper.”

That last remark explains how the week argued for CXL. Godbole told the HMEM workshop that customers holding about a million DDR4 DIMMs put them behind CXL, that Google and Meta use CXL only with old DDR4, and that new CXL memory “is more expensive, so it doesn’t really fit in the pyramid.” Its case rests on reuse. His joint paper with Micron reported that adding CXL modules to the DRAM channels of a Xeon 6 system raised read-only bandwidth 24% and mixed read and write bandwidth up to 39%, by interleaving pages across both kinds of memory. Software makes it harder. The TPage presenter put CXL latency at almost two to three times local DDR and said that moving pages between the two is often not worthwhile, so first placement matters most. The HMEM keynote on hotness tracking found the two best software methods for spotting hot pages both under 40% accurate, and a tracker built into the CXL device beat Linux’s automatic NUMA balancing by 24%.

Sharing that memory across hosts costs more again. Peiran Du’s group at UT Arlington ran a four-host CXL memory server with no hardware coherence between hosts, so software has to flush and fence every shared update.

CXL is for memory a site already owns

Sharing memory across hosts over CXL cost microseconds

Measured on one four-host CXL memory server, in microseconds, log scale

Dot chart on a log time axis from 10 nanoseconds to 1 millisecond. Claiming a graph vertex on one host takes about 100 nanoseconds. Publishing a write so another host sees it over CXL costs about 0.94 microseconds one way, against about 1.91 microseconds for an RDMA write over 400 gigabit Ethernet. A cross-host lock takes 3.7 microseconds at the median, claiming a vertex across hosts takes 3 to 5 microseconds, which the author called 30 to 50 times slower, and a contended lock reaches 132 microseconds at the 95th percentile.Operation0.010.11101001,000Time per operation, µs, log scaleClaim a vertexOne host0.1Publish a writeCXL, one way0.94RDMA write400Gb Ethernet, one way1.91Take a lockCXL, median3.7Claim a vertexAcross hosts3 to 5Contended lockCXL, 95th percentile132One hostAcross hosts, CXLRDMA
Figure 4 · Time per operation on a four-host CXL platform with no cross-host cache coherence, against an RDMA write and a single-host operation. Source: Du et al., Quantifying the Cost of Software-Managed Synchronization on Multi-Host CXL Memory, SC26 paper session, November 2026; one-way CXL and RDMA costs are the authors' estimates.

The authors estimated that publishing one write so another host sees it costs about 0.94 microseconds one way, about half their 1.91-microsecond estimate for an RDMA write over 400Gb Ethernet. A lock across hosts took a median of 3.7 microseconds at low contention and 132 microseconds at the 95th percentile when several hosts wanted the same lock, and claiming a graph vertex went from about 100ns on one host to 3 to 5 microseconds across hosts, “30 to 50 times slower.” Breadth-first search ran slower on four hosts than on one. In the discussion after the papers, one author called CXL memory “a poorer version, but cheaper, but open source version of NVLink,” and another noted that the one commercial CXL switch they could buy tops out at four hosts. Godbole himself had drawn the boundary in his exhibitor talk, with pools of eight or 16 hosts, CPUs at the center, and RDMA for anything bigger.

A new kind of memory got a harder hearing than reused DRAM. When an Oracle database developer asked the storage panel whether persistent memory would return, Ahmad questioned “that it’s actually useful for application developers,” and the questioner shot back, “As a database developer, I can assure you, sir, that it is very useful.” Phison’s Sebastien Jean gave the lesson he took from Optane, that “being two, three, four, 5X faster is not enough of a justification to move the industry.” Godbole’s answer at HMEM was shorter: “Optane is not coming back.” He meant that a new memory has to beat the cheaper option already on sale by far more than that, and CXL’s strongest case at SC26 rested on DIMMs a site had already paid for.

Keep the KV cache, or compute it again

The KV cache drew the most argument because it can always be rebuilt. A model that loses a conversation’s cache can recompute it from the prompt, so every place to keep it competes with recompute as well as with the other tiers. Mailthody said NVIDIA’s analysis found that recompute always wins at low token counts, where loading the cache is held up by latency, and loading wins once the transfer is limited by bandwidth. He said the crossover depends on the model and its attention design, so he wouldn’t give a number. Ahmad’s slides turned the same idea into a rule for storage, that the cache’s rebuild cost should set how much protection it gets. Our guide to keeping the cache or computing it again covers the trade in general terms.

What a shared tier bought

Vendors brought numbers for the loading side. Scality’s Candida Valois said reading a saved context back over RDMA was 14 times faster than recomputing it at 14,000 tokens and 72 times faster at 439,000 tokens, so the case for keeping the cache grows with the context. DDN’s Sanjay Jagad showed what happens when DRAM is the only overflow. In DDN’s test on one DGX B200, about 14.5% of prompt tokens were recomputed at 64 concurrent sessions and 25% at 96.

Keep the KV cache, or compute it again

With DRAM alone, DDN recomputed up to 25% of prompt tokens

DDN's own test on one DGX B200; dashed ticks mark the low end of the range

Horizontal bars in percent. DRAM only with 64 sessions: 14.5% of prompt tokens recomputed. DRAM only with 96 sessions: 25%. With a shared storage tier added to the same DRAM: 7% to 9%.Cache setup0102030Prompt tokens recomputed, %DRAM only64 sessions14.5%DRAM only96 sessions25%Shared tierSessions not stated7% to 9%DRAM aloneShared tier added
Figure 5 · Share of prompt tokens recomputed in DDN's test, with DRAM alone and with a shared storage tier added. Source: DDN exhibitor forum session, SC26, November 18, 2026; vendor-run test.

Adding a shared storage tier to the same DRAM held recompute to 7% to 9%, gave 1.2 to 1.3 times the requests in the same hour and cut mean time to first token by 54%. Jagad said 87% of the cache the shared tier served had been computed by other workers, which a cache private to one server can’t offer. Against a private NVMe cache on each server, the shared tier gave about 1.1 to 1.13 times the work and 36% to 40% lower time to first token. Restore time is the price. In DDN’s GB200 runs, reading back about 19GB from the shared tier took about 655 to 812ms, against about 300ms from host memory. These are DDN’s own tests.

VAST’s Glenn Lockwood gave the counterweight in the Modern High-Performance I/O tutorial, though VAST sells the shared option. These days “you don’t buy an AI system without in-node storage,” he said, and caching the KV cache globally means slower I/O than caching it on local NVMe, so “the relative cost of recomputing versus fetching from faraway storage starts skewing.” Hennecke reported that DAOS’s first MLPerf Storage KV cache results “weren’t as good,” and called the workload too early to judge.

What the cache costs the drives

Gibson argued for shared storage on throughput grounds and raised a cost nobody else mentioned. He cited a DeepSeek figure of about 20TB a day of KV cache written per GPU, against roughly 4TB a day that one drive of the size that fits in a GPU server can take at one drive write per day. Zhang proposed at the storage panel that the cache be sorted by lifetime. Request-local cache stays in HBM or DRAM and never touches an SSD, a conversation’s cache sits in DRAM or CXL and moves to SSD when idle, and long-lived prefixes such as system prompts get pinned in an SSD cache.

When there is nowhere left to keep it, a scheduler has to choose what to drop. The BidKV paper found a 128-fold median spread in how much memory different requests would free when the KV pool runs out, and choosing well cut the 95th-percentile time to first token from about 6,000ms to 631ms on vLLM. Other talks came at the cache from the network side. SK hynix’s Younghoon Min wants a CXL memory pool shared by GPU and CPU servers and said a small rack demo beat RDMA-connected setups, without numbers. Sandia’s Matthew Curry and NVIDIA described RDMA for S3-compatible object storage, which a partner measured at about three times TCP and which loaded models about 80% faster.

Drives chase 100M IOPS, and power sets the limit

The flash makers’ answer to the small, scattered reads of KV caches, vector search and graph training is a drive built for them. NVIDIA’s CJ Newburn opened the drive half of the storage panel by putting today’s PCIe 6.0 drives at about 5 to 6M random-read IOPS. Kioxia said it had demonstrated 20M IOPS of 512-byte reads and sees 100M on PCIe 7.0. SK hynix’s Zhang reported 27M on a PCIe 6.0 proof of concept with a 100M target, and Phison’s Jean said he is optimistic Phison can reach 100M too. Our Storage Next guide explains the design push behind those targets.

Drives chase 100M IOPS, and power sets the limit

Drive makers want 100M IOPS, and Phison showed what it costs

IOPS stated at the Emerging Storage Technology panel, and Phison’s power slide

Two bar charts. Left: random-read IOPS in millions. PCIe 6.0 drives today, 5 to 6 million. Kioxia's demonstration, 20 million. SK hynix's PCIe 6.0 proof of concept, 27 million. The PCIe 7.0 target from Kioxia, SK hynix and Phison, 100 million. A dashed line at 12.5 million marks where 4KB reads saturate the link, per Phison. Right: Phison's slide, a 25 watt drive climbing to 140 to 180 watts at eight times the IOPS on today's NAND, far beyond the connector limit.01 RANDOM READSRandom-read IOPS, millions02550751005 to 6MGen 6base20MKioxiademo27MSKhynix100MGen 7targetDrive or target02 THE POWER BILLDrive power, W05010015020025WToday’sdrive140 to 180W8x theIOPSPhison slideShownTargetPower estimate4KB ceiling 12.5M
Figure 6 · Left, random-read IOPS shown or targeted, with the line where 4KB reads saturate PCIe; right, Phison’s estimate of drive power at eight times the IOPS on today’s NAND. Source: Emerging Storage Technology panel and its public slides, SC26, November 18, 2026; makers’ demonstrations, targets and estimates.

Jean’s slides explained both the target and its cost. At 4KB per read, a drive saturates its link at about 12.5M IOPS, and only at 512 bytes does the same link carry 100M. With today’s NAND unchanged, he said, eight times the IOPS means eight times the plane activations and eight times the power, and his slide put a 25W drive at roughly 140 to 180W, “far beyond connector limit.” Zhang, on the same panel, wanted drives to stop reading 4KB to get 512 bytes, since NAND stores data in 16KB pages, and to filter data inside the drive so less of it crosses the link. He also said flash is cheap per gigabyte but expensive per unit of throughput in today’s market, which is why it suits cold data. Jean argued that drive makers can cut the DRAM that holds the address table, which saves little on one $40,000 drive but $5.7M per exabyte of drives.

Two papers went after the cost of flash in bulk. SuperSSD starts from the fact that SSDs are about 80% of an all-flash enclosure’s cost, treats a whole enclosure of consumer drives as one SSD, and reported 46.3% lower cost of ownership than a CPU-based enclosure in its authors’ model. DNoF lets the CPU and a DPU serve the same NVMe over Fabrics drives at once, for 2.36 times the throughput of the DPU alone.

Bigger drives save power and stretch rebuilds

Lockwood’s exhibitor talk, 900 Petabytes and Not a Watt More, showed the other side of Zhang’s point. Flash is priced by capacity, but its performance costs power, so larger drives cut a system’s power for the same capacity at the price of less bandwidth. VAST runs a 60PB file system on 15TB drives that delivers about 14TB/s and another of just over 900PB on 122TB drives that delivers 8TB/s, and both draw about 400kW.

Bigger drives save power and stretch rebuilds

VAST: storage power follows bandwidth and drive count

Two deployed VAST file systems and Lockwood’s model of the larger one, kW

Horizontal bars of power in kilowatts. A deployed 60 petabyte VAST system on 15 terabyte drives, about 14 terabytes per second, draws about 400. A deployed 900 petabyte system on 122 terabyte drives, 8 terabytes per second, also draws about 400. By VAST's model, the same 900 petabytes on 15 terabyte drives would draw about 5,600 for 190 terabytes per second, and on 245 terabyte drives about 190.System and drives01500300045006000Power, kW60PB, deployed15TB drives, 14TB/s400kW900PB, deployed122TB drives, 8TB/s400kW900PB, model15TB drives, 190TB/s5.6MW900PB, model245TB drives190kWDeployedVAST model
Figure 7 · Power of two deployed VAST file systems, and of the 900PB one rebuilt on smaller or larger drives by VAST’s linear model of about 28W per SSD plus 20W per GB/s. Source: Glenn Lockwood, VAST Data, 900 Petabytes and Not a Watt More, SC26 exhibitor forum, November 17, 2026; VAST’s own systems and model.

Across VAST’s clusters, Lockwood fitted every SSD at about 28W and every GB/s delivered at about 20W, with no term for capacity. By that model, the 900PB system built on 15TB drives would take about 5.6MW, the power of about 3,100 Blackwell Ultra GPUs, and on 245TB drives it would take about 190kW. With 15TB drives, he added, nothing larger than about 250PB fits in a 400kW envelope at all, by his chart.

Rebuild time is what bigger drives give up, and VAST simulated it on the same 900PB system with its own failure data. These odds are that model’s results for this one system, and the talk did not give every assumption behind them. Double parity, common in open-source Lustre and BeeGFS setups, gave a one in 150 chance of losing data over 10 years, and the declustered RAID inside one enclosure that proprietary file systems use gave one in 620. Swapping in the petabyte SSDs on flash makers’ roadmaps pushed that to one in 11. Spreading each rebuild across the whole system cut rebuild time from eight days per petabyte drive to one hour, and adding a parity drive on top brought the odds to one in 54 million. Lockwood’s warning was that the metadata drives, which VAST copies three times for low latency, then become the weak point, at one in 58 million against one in 78 trillion for the data drives.

Buy the bandwidth the work uses

If performance costs power, the next question is how much of it a site needs. Lockwood’s tutorial answer for training was less than most people buy. A transformer’s checkpoint runs about 14 bytes per parameter, so a trillion-parameter model writes about 14TB, and draining that within a minute takes about 230GB/s (14TB / 60s), which he rounded to the order of 200GB/s. VAST’s own telemetry very rarely sees more than 100 or 200GB/s of checkpoint traffic at any customer site. “If people are telling you, you need 10 or 20 terabytes per second to train a model,” he said, “do the math yourself.” Google’s Dean Hildebrand added the buyer’s side at the gigawatt panel: “A lot of people’s storage systems are sitting 80% idle.”

The PDSW workshop showed how far even good software falls short of a file system’s peak. The ADIOS team’s WarpX output reached 3.6TB/s on Frontier, whose file system the speaker put at about 8TB/s, and 1.7TB/s of about 5TB/s on Perlmutter.

Buy the bandwidth the work uses

One science code reached under half of Frontier’s 8TB/s

ADIOS output from WarpX, against each file system’s stated peak, TB/s

Vertical bars in terabytes per second. Frontier: a stated peak of about 8, a reached rate of 3.6, and an effective 7 once the output was compressed. Perlmutter: a stated peak of about 5 and a reached rate of 1.7. The speaker added that skewed output from the boosted-frame diagnostics ran about 100 times slower than uniform output on a smaller system.Write rate, TB/s024688TB/sFrontierpeak3.6TB/sFrontierreached7TB/sFrontiercompressed5TB/sPerlmutterpeak1.7TB/sPerlmutterreachedSystem and measureStated peakReachedEffective, compressed
Figure 8 · Write rate reached by well-distributed WarpX output through ADIOS against the file system peak the speaker gave; the compressed bar is an effective rate. Source: ADIOS and WarpX talk, PDSW workshop, SC26, November 16, 2026; peaks as the speaker stated them.

Those were the good runs. Skewed output from the same simulation ran about 100 times slower than uniform output on a smaller system. Zhaobin Zhu of Mainz showed that a busy Lustre storage target can take over a second to answer a write that a quiet one answers in about 100ms, and that steering writes to the quiet targets made them 24% to 55% faster. Izzet Yildirim’s GDSight found that NVIDIA’s cuFile library sends reads under 16KB through an ordinary POSIX read, 91% of the operations in its test, while the GPUDirect Storage counters reported nothing wrong. “Healthy counters don’t mean healthy I/O,” he said. Packing small KV entries before NIXL read them raised read throughput 17 times. A slow GPUDirect case at the HDF5 session turned out to be “really a file layout problem.”

The IO500 production list put Argonne’s Aurora on top with a score of 46,192.01 on DAOS, up from its previous score of 32,165.90, with about 12TB/s of bandwidth and 173 million metadata operations a second. Most of the IO500 session was about keeping that kind of peak honest. Organizers said one submitter’s random reads had come out faster than its sequential reads on a small dataset, which they called “physically impossible” for the test as designed, so the random-read phase is being rebuilt to defeat caching. They also said “the find score has gotten super out of hand” on the research lists, and one entry was removed this round for not following the intent of the rules. The Green500 session put the power trend behind all of it, with Frontier at 400kW per rack and a projection of one to two megawatts per rack by 2030.

On the show floor

Announcements around the conference filled in hardware the sessions talked about. Micron published the clearest storage number. On six MinIO AIStor nodes with sixty Micron 6600 ION 122TB SSDs, switching the traffic between nodes from TCP to RDMA lifted peak GET throughput from 137.7GB/s to 187.0GB/s in Micron’s own test, while CPU use on writes fell from 78.1% to 35.6%.

On the show floor

RDMA lifted reads on Micron's 122TB-drive cluster, not writes

MinIO AIStor on six nodes with 60 Micron 6600 ION 122TB SSDs

Horizontal bars in gigabytes per second. GET over RDMA 187.0, GET over TCP 137.7, PUT over RDMA 72.8, PUT over TCP 72.9.Operation050100150200Throughput, GB/sGET over RDMA64MB objects, peak187.0 GB/sGET over TCP64MB objects, peak137.7 GB/sPUT over RDMA64MB objects72.8 GB/sPUT over TCP64MB objects72.9 GB/sRDMATCP
Figure 9 · Throughput Micron measured with MinIO AIStor over TCP and over RDMA. Source: Micron blog, MinIO AIStor on Micron 6600 ION 122TB SSDs, November 17, 2026; Micron's own test.

WEKA published a KV cache test it ran with Nebius on one eight-GPU HGX B300 node serving 512 sessions for eight hours. Pooling NVMe as a shared context tier gave 3.7x the output tokens per GPU-hour of HBM-only serving, cut the prefill work recomputed from 60% to 6.8%, and raised the share of requests with a first token inside five seconds from 44% to 97%. It is a vendor-run test, and its baseline had no DRAM or local flash tier at all.

Supermicro said its first PCIe 6.0 all-flash servers hold up to 32 E3.S drives and 3.93PB on 122TB SSDs. Phison’s X3 controller targets up to 28GB/s and 6.8M IOPS, and Silicon Motion’s SM8466 lists up to 28GB/s and 7M IOPS. Dell announced liquid-cooled storage for the first half of 2027, DDN made EXAScaler available as software, and VAST added job-level quality of service. On the memory side, SK hynix showed HBM4E, HBM4 and HBM3E beside a 256GB 3DS DDR5 RDIMM, AMD described the Instinct MI430X with 432GB of HBM4, and Penguin announced a photonic memory appliance with Marvell, sampling in the second half of 2027.

More from the program

These sessions on the program also dealt with memory or storage. Each links to its program page.

More from the program

Memory and storage ran through every day of the program

Sessions in the table below that the sections above do not cover

Four columns, Monday to Thursday. Monday: an AI storage tutorial, sorting on processing-in-memory DIMMs, DAOS as a burst buffer, and a tool for copying billions of files. Tuesday: storage power and bandwidth, Z-SPDK compressed I/O and OASIS object storage. Wednesday: photonic memory pools, backup at billion-file scale and thin-provisioned cloud storage. Thursday: COPPER DRAM error correction and vector search on processing-in-memory hardware. Memory sessions are light teal, storage sessions dark teal.MONDAYSorting inmemoryDAOS burstbufferCopyingbillions offilesTUESDAYZ-SPDKcompressed I/OOASIS objectstorageWEDNESDAYPhotonic memorypoolsBillion-filebackupThin-provisionedstorageTHURSDAYCOPPER DRAMerrorcorrectionVector searchin memoryMemoryStorage
Figure 10 · Other SC26 memory and storage sessions, placed on their days, by what they dealt with. Source: SC26 program, sc26.conference-program.com, November 15 to 20, 2026.
Day Session Presenters What it covered
Monday Large Scale Sorting on UPMEM Northern Arizona University Sorting on processing-in-memory DIMMs, where the energy saving mattered more than the speed
Monday DAOS as a burst buffer Jefferson Lab Streaming detector data across a wide-area network into DAOS instead of a POSIX file system
Monday Copy2 Georgia Tech A copy tool built for a migration of 3.3 billion files and three petabytes
Tuesday Z-SPDK University of Florida, UC Merced, Argonne Lossy-compressed I/O fast enough to keep up with NVMe SSDs
Tuesday OASIS Sogang University, SK hynix, Los Alamos Running scientific SQL operators inside object storage
Wednesday Photonics for AI and HPC Marvell, Micron, Penguin Solutions Pooling HBM and DDR over optical links so memory is not stranded in one server
Wednesday Incremental backup at billion-file scale Bacula Systems Backing up GPFS, Lustre and ZFS from their own change records instead of scanning every directory
Wednesday No Disk Left Behind ETS Montreal, OVHcloud Predicting cloud disk use so hosts can carry less SSD capacity
Thursday COPPER Huazhong University of Science and Technology Making on-die and rank-level DRAM error correction work together
Thursday PIMCQG Hong Kong Baptist University Billion-scale vector search on processing-in-memory hardware

What I’d watch

SC26 lacked the one test that would settle its main argument. DDN measured shared storage against DRAM and private NVMe, WEKA measured pooled NVMe against HBM alone, SK hynix compared its CXL pool with RDMA setups without numbers, and the CXL papers measured synchronization costs. No session I watched put CXL memory, local NVMe and shared storage under the same inference job, with recompute as the fourth option. That comparison would need each tier’s latency, bandwidth, hit rate, endurance and total system cost on the same workload, and Mailthody’s point says it would need several context lengths too, since the answer moves with them.

What I’d watch

No session I watched compared CXL memory with NVMe or shared storage

What the covered sessions offered as evidence for each tier

Four stacked rows, one per tier. HBM and DRAM: DDN's vendor-run test with DRAM alone, shown as a solid teal tag. CXL pool: compared with RDMA network setups only, shown dashed. Local flash: demonstrations and PCIe 7.0 targets from the makers, shown in dark teal. Shared storage: the same DDN test, shown as a solid teal tag.01 HBM AND DRAMVendor-run, one testDDN test, DRAM alone02 CXL POOLSK hynix demo, no values heardCompared with RDMA only03 LOCAL FLASHPanel figures, makers' ownDemos and targets04 SHARED STORAGEVendor-run, one testDDN test, same oneVendor-run testDemos and targetsRDMA baseline only
Figure 11 · The evidence behind each tier in the SC26 sessions covered here; DDN's one test appears on two tiers. Source: SC26 sessions covered on this page, November 18, 2026.

Two dates matter for how that test would come out. If Godbole’s memory makers are right that supply recovers starting maybe 2028, new DRAM gets cheaper and the case for reused DDR4 behind CXL weakens with it. Power won’t ease on the same schedule. By Jean’s figures, the 25W drives in today’s slots would need roughly 140 to 180W at eight times their IOPS, and Evans’s numbers say each GPU generation widens the gap between HBM and everything behind it. Until that test exists, the moves with numbers behind them this week were the modest ones: reuse old DIMMs, share cache across workers, read smaller blocks, and size bandwidth to the checkpoint. Friday’s Empty Shelf panel on hard drive and tape supply had no recording posted when I wrote this, and its abstract blames the supply squeeze on a market with few makers and few buyers, so it is the session I’d watch next.

Sources

Primary is the original paper, standard or datasheet. Secondary is a review, a vendor summary or a news report. Measured is my own test data.

Show all 41 sources, 40 primary